Pig Hoof Scalding Machine | HT-P618-II
Pig Hoof Scalding Machine. Compare product range, residence time and utility conditions; share your requirements for configuration review.

Specification notes
| Model | HT-P618-II |
|---|---|
| Out size | 2500*1000*1140 mm(L*W*H) |
| Component and material | 1)Hot galvanized steel or Stainless steel 8# U-steel main frame and tank body frame 2) Stainless steel plate plate (3mm) 3) Polyurethane insulation materials (70mm) 4) Hot galvanized steel or Stainless steel steam heating pipe 5) Drain valve 6) Thermometer |
| Data status | Source reference R1; configuration requires written confirmation |
Use and process role
For line designers, the Pig Hoof Scalding Machine provides a heated-water system that conditions pig skin, heads or hooves before mechanical hair removal. Its value depends on the hand-off before and after the machine, so the rail, floor level and controls should be reviewed together. The HT listing supplies reference data for the offered arrangement; those figures are reproduced below for comparison. For export quotations, confirm voltage, materials, guarding, spare parts and documentation before the purchase order is released.
Structure and working principle
Product is immersed, sprayed or conveyed through controlled hot water for a set time. Temperature and exposure loosen hair without unnecessary heat damage, after which the item moves directly to the dehairing step. Cleaning access and safe isolation are part of the operating principle, not optional extras.
Source-listed construction and features
Stable scalding temperature
Exposure time matched to the product
Insulated tank or enclosure options
Controlled overflow and drainage
Safe loading and discharge
Access for sediment removal
Applications and integration
The usual application is pig carcass, head and hoof preparation lines ahead of dehairing or finishing. It can be specified for a new line or adapted to a retrofit, provided that the existing supports, working heights, utilities and control signals are measured on site. Plants handling several pig sizes should state the full range rather than quoting only an average.
Selection conditions and project fit
Define product size, residence time, line speed, water quality, temperature, pressure, flow and drainage. Specify the hygiene process and acceptance method; a machine name does not establish a validated hygiene result.
Evidence, configuration and document status
The descriptions and tables below are source-listed reference information, not independently measured results. Confirm material grade, electrical supply, dimensions, duty, guards, controls and delivery scope in the approved quotation and drawing. No model-specific certificate or verified customer installation is established by this page. Request the document issuer, applicable model, scope and revision before relying on a compliance claim.
Source and version
Reference compilation R1, 2026-11-16. Supplied document: 2. 烫脱毛,剥皮,掏脏设备.doc; section 2.3. Configuration rows retain source units. Where the source lists alternatives or several models, each row must be checked as a separate configuration; a capacity or dimension must not be transferred between models.
Installation and process interfaces
State incoming product condition, process residence time, line speed, working height, water connections, drain location and access for cleaning or component removal. Check the full installation envelope, not only catalogue dimensions.
Utilities, control and feedback requirements
Use only the power, water, heating or cooling values given for the matching source configuration. Confirm operating pressure/flow or temperature, control method and line signals. A reference machine does not establish a validated hygiene or cooling result.
Maintenance and part identification
Request the configuration-specific manual and part references for nozzles, seals, pumps, sensors, conveying elements and any heating/cooling components fitted. Agree quantities and replenishment needs against actual duty and delivery experience. This page does not prescribe maintenance intervals, repairs or a guaranteed stock position.
Configuration-specific document checklist
Before purchase, identify the complete model and suffix, configuration table and drawing revision. Request the applicable layout/interface drawing, specification, manual, parts list and agreed inspection or test records. Performance curves or certificates should be linked only when an applicable original exists; a reference summary is not a substitute.
Source-unit confirmation required
The supplied reference does not explicitly state a unit for these fields: Water temperature. The original entries are retained rather than assigning an assumed unit. Confirm the units, matching configuration and operating conditions before comparing these figures or approving a quotation.
Compare configurations for your project
For Pig Hoof Scalding Machine | HT-P618-II, keep the complete identifier HT-P618-II attached to its own source configuration. Compare process duty, incoming animal or product range, target output, utilities, installation envelope and upstream/downstream interfaces under the same project conditions. A higher catalogue rate alone does not establish a better fit.
Start with this page's listed reference fields: Out size: 2500*1000*1140 mm(L*W*H); Component and material: 1)Hot galvanized steel or Stainless steel 8# U-steel main frame and tank body frame 2) Stainless steel plate plate (3mm) 3) Polyurethane insulation materials (70mm) 4) Hot galvanized steel or Stainless steel steam heating pipe 5) Drain valve 6) Thermometer. Confirm units, conditions and revision against the quoted configuration; do not transfer values to another model.
Compare alternative quotations only after each supplier identifies the complete model, configuration and matching documents. No universal suffix meaning or unsupported advantage over another model is asserted.
Purchasing review and enquiry preparation
Start with Pig Hoof Scalding Machine | HT-P618-II and its specification/source notes. Download the linked reference summary, then request the original configuration-specific drawing and current technical documents. The summary is not an approved drawing, certificate or acceptance record.
Use the linked pig processing application and purchasing guidance to review process interfaces, selection conditions and the proposed supply boundary. Verify which manufacturer, supplier and installation responsibilities are included; a reference photo does not establish factory ownership, certification or a completed HUATAO installation.
Before enquiry, prepare animal species or incoming product, size/weight range, target throughput, operating shifts, destination, available utilities and a layout or interface drawing. Quote HT-P618-II and identify the missing documents or conditions you need checked. Use the enquiry on this page so the product and original source page are retained.
| Parameter | Reference Value / Buyer Check |
|---|---|
| Model | HT-P618-II |
| Application | Which main used to scald pig hooves for dehairing |
| Out size | 2500*1000*1140 mm(L*W*H) |
| Working principle | steam heating way or electric |
| Water temperature | 58-62 ℃ |
| Component and material | 1)Hot galvanized steel or Stainless steel 8# U-steel main frame and tank body frame 2) Stainless steel plate plate (3mm) 3) Polyurethane insulation materials (70mm) 4) Hot galvanized steel or Stainless steel steam heating pipe 5) Drain valve 6) Thermometer |
| Quotation control | Confirm product size, batch or continuous duty, capacity, target temperature, heat source, water volume, make-up rate, exhaust and effluent arrangements. |
Buyer FAQ
What information is needed to quote the Pig Hoof Scalding Machine?
Confirm product size, batch or continuous duty, capacity, target temperature, heat source, water volume, make-up rate, exhaust and effluent arrangements.
Which spare parts should be ordered with the machine?
Start with the normal wear and hygiene parts for this duty: bearings, seals, sensors, chains or belts, nozzles, blades, scrapers, pneumatic parts and electrical protection devices as applicable. The supplier should issue a model-specific list.
Are the published technical figures final?
No. The table records reference information from the citedHTpage. Capacity, power, dimensions, material grade and utilities must be confirmed on the quotation and approved drawing.
How should the equipment be accepted after installation?
Use a documented site-acceptance test covering alignment, guards, emergency stops, interlocks, dry running, representative load, cleaning access, leakage or drainage, operator training and delivery of manuals and spares.
What information is needed to select this equipment?
Define product size, residence time, line speed, water quality, temperature, pressure, flow and drainage. Specify the hygiene process and acceptance method; a machine name does not establish a validated hygiene result.
Are these specifications an approved supply commitment?
No. These are source reference details. The quotation must identify the exact configuration, drawing revision, included documents and agreed acceptance criteria.
Related configurations and guidance
Reference specification and document status
Download HT-P618-II reference specification and verification checklist
This reference is not an approved manufacturing drawing, inspection report or certificate. Request the configuration-specific documents before purchase.