Grid-Belt Pork Deboning Conveyor | HT-P605-I
Grid-Belt Pork Deboning Conveyor. Compare input range, required output and working interfaces; share your requirements for configuration review.

Specification notes
| Model | HT-P605-I |
|---|---|
| Rated voltage/Phase/Frequency | 380V/3P/50HZ |
| Power | 0.75kw |
| Out size | 6000*720*800mm(L*W*H) |
| Component and material | 1) Stainless steel square tube frame (60*40*2mm and 38*25*2mm) 2) Polyoxymethylene module network belt 3) Stainless steel driving shafts and roller 4) Frequency control |
| Data status | Source reference R1; configuration requires written confirmation |
Use and process role
For line designers, the Grid-Belt Pork Deboning Conveyor provides a downstream pork cutting or deboning station that organizes product while operators or blades make the required cuts. Its value depends on the hand-off before and after the machine, so the rail, floor level and controls should be reviewed together. The HT listing supplies reference data for the offered arrangement; those figures are reproduced below for comparison. For export quotations, confirm voltage, materials, guarding, spare parts and documentation before the purchase order is released.
Structure and working principle
Carcass sections or primals are supported and presented at a controlled working height. A saw, knife station or multi-level conveyor separates cuts and routes meat, bone and trim to their designated outlets. Cleaning access and safe isolation are part of the operating principle, not optional extras.
Source-listed construction and features
Orderly separation of meat, bone and trim
Working height suited to operators
Food-contact surfaces designed for cleaning
Belt or table width matched to product
Safe tool and blade positions
Interfaces to packing and crate handling
Applications and integration
The usual application is pork primal cutting, deboning, trimming and packing rooms. It can be specified for a new line or adapted to a retrofit, provided that the existing supports, working heights, utilities and control signals are measured on site. Plants handling several pig sizes should state the full range rather than quoting only an average.
Selection conditions and project fit
Provide rail or belt dimensions, working height, travel direction, carrier spacing, load range, speed and upstream/downstream connection drawings. A similar-looking carrier is not proof of fit.
Evidence, configuration and document status
The descriptions and tables below are source-listed reference information, not independently measured results. Confirm material grade, electrical supply, dimensions, duty, guards, controls and delivery scope in the approved quotation and drawing. No model-specific certificate or verified customer installation is established by this page. Request the document issuer, applicable model, scope and revision before relying on a compliance claim.
Source and version
Reference compilation R1, 2026-11-16. Supplied document: 2. 烫脱毛,剥皮,掏脏设备.doc; section 2.7. Configuration rows retain source units. Where the source lists alternatives or several models, each row must be checked as a separate configuration; a capacity or dimension must not be transferred between models.
Installation and process interfaces
Provide product size and condition, target cut or separation, feed/discharge direction, support height and space for tool replacement and maintenance. Confirm the proposed guards, operator access and connection to the receiving station.
Utilities, control and feedback requirements
Check the model-specific drive and electrical or fluid-power supply. Agree start/stop, upstream/downstream interlocks and feedback requirements where relevant. Do not infer a control protocol or tool capability from a family photograph.
Maintenance and part identification
Request the configuration-specific manual and part references for matched blades or tools, drive components, seals and position sensors where fitted. Agree quantities and replenishment needs against actual duty and delivery experience. This page does not prescribe maintenance intervals, repairs or a guaranteed stock position.
Configuration-specific document checklist
Before purchase, identify the complete model and suffix, configuration table and drawing revision. Request the applicable layout/interface drawing, specification, manual, parts list and agreed inspection or test records. Performance curves or certificates should be linked only when an applicable original exists; a reference summary is not a substitute.
Compare configurations for your project
For Grid-Belt Pork Deboning Conveyor | HT-P605-I, keep the complete identifier HT-P605-I attached to its own source configuration. Compare process duty, incoming animal or product range, target output, utilities, installation envelope and upstream/downstream interfaces under the same project conditions. A higher catalogue rate alone does not establish a better fit.
Start with this page's listed reference fields: Rated voltage/Phase/Frequency: 380V/3P/50HZ; Power: 0.75kw; Out size: 6000*720*800mm(L*W*H); Component and material: 1) Stainless steel square tube frame (60*40*2mm and 38*25*2mm) 2) Polyoxymethylene module network belt 3) Stainless steel driving shafts and roller 4) Frequency control. Confirm units, conditions and revision against the quoted configuration; do not transfer values to another model.
Compare alternative quotations only after each supplier identifies the complete model, configuration and matching documents. No universal suffix meaning or unsupported advantage over another model is asserted.
Purchasing review and enquiry preparation
Start with Grid-Belt Pork Deboning Conveyor | HT-P605-I and its specification/source notes. Download the linked reference summary, then request the original configuration-specific drawing and current technical documents. The summary is not an approved drawing, certificate or acceptance record.
Use the linked pig processing application and purchasing guidance to review process interfaces, selection conditions and the proposed supply boundary. Verify which manufacturer, supplier and installation responsibilities are included; a reference photo does not establish factory ownership, certification or a completed HUATAO installation.
Before enquiry, prepare animal species or incoming product, size/weight range, target throughput, operating shifts, destination, available utilities and a layout or interface drawing. Quote HT-P605-I and identify the missing documents or conditions you need checked. Use the enquiry on this page so the product and original source page are retained.
| Parameter | Reference Value / Buyer Check |
|---|---|
| Model | HT-P605-I |
| Application | Which main used to convey pig carcass for boneless |
| Rated voltage/Phase/Frequency | 380V/3P/50HZ |
| Power | 0.75kw |
| Out size | 6000*720*800mm(L*W*H) |
| Component and material | 1) Stainless steel square tube frame (60*40*2mm and 38*25*2mm) 2) Polyoxymethylene module network belt 3) Stainless steel driving shafts and roller 4) Frequency control |
| Quotation control | Define the cutting pattern, pieces per hour, product temperature, belt width, operator count, waste routes, tool sterilization and pack-out format. |
Buyer FAQ
What information is needed to quote the Grid-Belt Pork Deboning Conveyor?
Define the cutting pattern, pieces per hour, product temperature, belt width, operator count, waste routes, tool sterilization and pack-out format.
Which spare parts should be ordered with the machine?
Start with the normal wear and hygiene parts for this duty: bearings, seals, sensors, chains or belts, nozzles, blades, scrapers, pneumatic parts and electrical protection devices as applicable. The supplier should issue a model-specific list.
Are the published technical figures final?
No. The table records reference information from the citedHTpage. Capacity, power, dimensions, material grade and utilities must be confirmed on the quotation and approved drawing.
How should the equipment be accepted after installation?
Use a documented site-acceptance test covering alignment, guards, emergency stops, interlocks, dry running, representative load, cleaning access, leakage or drainage, operator training and delivery of manuals and spares.
What information is needed to select this equipment?
Provide rail or belt dimensions, working height, travel direction, carrier spacing, load range, speed and upstream/downstream connection drawings. A similar-looking carrier is not proof of fit.
Are these specifications an approved supply commitment?
No. These are source reference details. The quotation must identify the exact configuration, drawing revision, included documents and agreed acceptance criteria.
Related configurations and guidance
Reference specification and document status
Download HT-P605-I reference specification and verification checklist
This reference is not an approved manufacturing drawing, inspection report or certificate. Request the configuration-specific documents before purchase.