Pig Red and White Offal Evisceration Platform | HT-P511-VII
Pig Red and White Offal Evisceration Platform. Compare load range, dimensions and process interfaces; share your requirements for configuration review.

Specification notes
| Model | HT-P511-VII |
|---|---|
| Out size | 2100*1000*800mm (L*W*H) |
| Component and material | 1) Hot galvanized steel or Stainless steel support column (diameter:∮159mm) 2) Hot galvanized steel or Stainless steel main frame (60*40*2mm) 3) Hot galvanized steel or Stainless steel ladder and handrail 4)Anti-skid plastic square (25mm) 5)Include one set hand washing/knives sterilizing device and one set apron washing device |
| Data status | Source reference R1; configuration requires written confirmation |
Use and process role
This Pig Red and White Offal Evisceration Platform is specified for one practical job: a hygienic machine or workstation for transferring, washing, scraping, draining, inspecting or packing edible offal. A reliable installation begins with correct interface dimensions and a realistic duty cycle. The HT listing supplies reference data for the offered arrangement; those figures are reproduced below for comparison. For export quotations, confirm voltage, materials, guarding, spare parts and documentation before the purchase order is released.
Structure and working principle
Offal is loaded into the working area and moved, agitated, scraped or rinsed according to the task. Water and residues leave through a controlled drain or collection point, while cleaned product exits to inspection, chilling or packing. The upstream machine must not feed faster than the receiving station can clear.
Source-listed construction and features
Separate routing for the specified offal stream
Smooth food-contact surfaces
Controlled water and residue discharge
Safe access for loading and unloading
Cleaning access around moving parts
Layout compatible with inspection flow
Applications and integration
The usual application is white-offal and red-offal rooms in pig abattoirs and pork processing plants. It can be specified for a new line or adapted to a retrofit, provided that the existing supports, working heights, utilities and control signals are measured on site. Plants handling several pig sizes should state the full range rather than quoting only an average.
Selection conditions and project fit
State product or animal range, required duty and throughput, available space, utilities, connection dimensions and delivery scope. Confirm the configuration and acceptance criteria in writing.
Evidence, configuration and document status
The descriptions and tables below are source-listed reference information, not independently measured results. Confirm material grade, electrical supply, dimensions, duty, guards, controls and delivery scope in the approved quotation and drawing. No model-specific certificate or verified customer installation is established by this page. Request the document issuer, applicable model, scope and revision before relying on a compliance claim.
Source and version
Reference compilation R1, 2026-11-16. Supplied document: 2. 烫脱毛,剥皮,掏脏设备.doc; section 2.9. Configuration rows retain source units. Where the source lists alternatives or several models, each row must be checked as a separate configuration; a capacity or dimension must not be transferred between models.
Installation and process interfaces
Provide the load and product range, travel direction, rail/belt section or mating geometry, working heights, supports and maintenance clearances. Similar appearance is not proof of fit.
Utilities, control and feedback requirements
For powered equipment, confirm the matching drive, supply, control and line signals. For passive components, confirm mechanical interfaces and any requirements of the receiving equipment; no powered or feedback capability should be assumed.
Maintenance and part identification
Request the configuration-specific manual and part references for rollers, chains, hooks, bearings, guides and drive elements where applicable. Agree quantities and replenishment needs against actual duty and delivery experience. This page does not prescribe maintenance intervals, repairs or a guaranteed stock position.
Configuration-specific document checklist
Before purchase, identify the complete model and suffix, configuration table and drawing revision. Request the applicable layout/interface drawing, specification, manual, parts list and agreed inspection or test records. Performance curves or certificates should be linked only when an applicable original exists; a reference summary is not a substitute.
Compare configurations for your project
For Pig Red and White Offal Evisceration Platform | HT-P511-VII, keep the complete identifier HT-P511-VII attached to its own source configuration. Compare process duty, incoming animal or product range, target output, utilities, installation envelope and upstream/downstream interfaces under the same project conditions. A higher catalogue rate alone does not establish a better fit.
Start with this page's listed reference fields: Out size: 2100*1000*800mm (L*W*H); Component and material: 1) Hot galvanized steel or Stainless steel support column (diameter:∮159mm) 2) Hot galvanized steel or Stainless steel main frame (60*40*2mm) 3) Hot galvanized steel or Stainless steel ladder and handrail 4)Anti-skid plastic square (25mm) 5)Include one set hand washing/knives sterilizing device and one set apron washing device. Confirm units, conditions and revision against the quoted configuration; do not transfer values to another model.
Compare alternative quotations only after each supplier identifies the complete model, configuration and matching documents. No universal suffix meaning or unsupported advantage over another model is asserted.
Purchasing review and enquiry preparation
Start with Pig Red and White Offal Evisceration Platform | HT-P511-VII and its specification/source notes. Download the linked reference summary, then request the original configuration-specific drawing and current technical documents. The summary is not an approved drawing, certificate or acceptance record.
Use the linked pig processing application and purchasing guidance to review process interfaces, selection conditions and the proposed supply boundary. Verify which manufacturer, supplier and installation responsibilities are included; a reference photo does not establish factory ownership, certification or a completed HUATAO installation.
Before enquiry, prepare animal species or incoming product, size/weight range, target throughput, operating shifts, destination, available utilities and a layout or interface drawing. Quote HT-P511-VII and identify the missing documents or conditions you need checked. Use the enquiry on this page so the product and original source page are retained.
| Parameter | Reference Value / Buyer Check |
|---|---|
| Model | HT-P511-VII |
| Application | Which main used for pig red viscera remove |
| Out size | 2100*1000*800mm (L*W*H) |
| Component and material | 1) Hot galvanized steel or Stainless steel support column (diameter:∮159mm) 2) Hot galvanized steel or Stainless steel main frame (60*40*2mm) 3) Hot galvanized steel or Stainless steel ladder and handrail 4)Anti-skid plastic square (25mm) 5)Include one set hand washing/knives sterilizing device and one set apron washing device |
| Quotation control | Identify the organ or product, hourly load, batch size, cleaning result, water pressure, drain, working height and destination after the operation. Do not combine red and white offal routes without a hygiene review. |
Buyer FAQ
What information is needed to quote the Pig Red and White Offal Evisceration Platform?
Identify the organ or product, hourly load, batch size, cleaning result, water pressure, drain, working height and destination after the operation. Do not combine red and white offal routes without a hygiene review.
Which spare parts should be ordered with the machine?
Start with the normal wear and hygiene parts for this duty: bearings, seals, sensors, chains or belts, nozzles, blades, scrapers, pneumatic parts and electrical protection devices as applicable. The supplier should issue a model-specific list.
Are the published technical figures final?
No. The table records reference information from the citedHTpage. Capacity, power, dimensions, material grade and utilities must be confirmed on the quotation and approved drawing.
How should the equipment be accepted after installation?
Use a documented site-acceptance test covering alignment, guards, emergency stops, interlocks, dry running, representative load, cleaning access, leakage or drainage, operator training and delivery of manuals and spares.
What information is needed to select this equipment?
State product or animal range, required duty and throughput, available space, utilities, connection dimensions and delivery scope. Confirm the configuration and acceptance criteria in writing.
Are these specifications an approved supply commitment?
No. These are source reference details. The quotation must identify the exact configuration, drawing revision, included documents and agreed acceptance criteria.
Related configurations and guidance
Reference specification and document status
Download HT-P511-VII reference specification and verification checklist
This reference is not an approved manufacturing drawing, inspection report or certificate. Request the configuration-specific documents before purchase.