Duck Wax Cooling Pool for Poultry Processing Line
Duck Wax Cooling Pool. Compare product range, residence time and utility conditions; share your requirements for configuration review.

Specification notes
| Model | HT-WCP, HT-WCP1000, HT-WCP10000, HT-WCP3000, HT-WCP6000 |
|---|---|
| Configuration basis | Multiple source variants; review the separate tables below |
| Data status | Reference information; confirm exact model and drawing revision |
Use and process role
Stainless Steel Poultry Wax Cooling Tank for Duck & Goose Slaughterhouse
The Automatic Duck Wax Cooling Pool is an essential component in modern waterfowl processing lines, designed to cool and solidify the wax coating after the duck or goose waxing process.
Unlike chickens, ducks and geese contain a large number of fine feathers and down that are difficult to remove completely through conventional plucking equipment. Therefore, many commercial duck processing plants use wax dipping technology to capture remaining feathers.
After the carcass passes through the wax dipping section, it enters the wax cooling pool. The cold water rapidly reduces the temperature of the wax layer, causing the wax to become solid and firmly attached to the remaining fine feathers.
After cooling, the carcass enters the dewaxing machine where the hardened wax layer is removed.
Huatao wax cooling pool is designed with:
Food grade stainless steel construction
Stable cooling performance
Continuous conveyor operation
Easy cleaning and maintenance
The equipment is widely used in:
Duck slaughterhouses
Goose processing plants
Waterfowl export processing factories
A properly controlled wax cooling process improves feather removal efficiency and final carcass appearance.
Structure and working principle
The duck carcasses coated with liquid wax enter the cooling pool through the overhead conveyor system.
Inside the cooling tank:
Cold water continuously contacts the wax-coated carcass surface.
Heat is transferred from the wax layer to the cooling medium.
The wax gradually changes from liquid state into a hard solid layer.
The hardened wax captures remaining fine feathers.
The carcasses move to the dewaxing machine for wax peeling.
The cooling temperature and residence time can be adjusted according to:
Duck size
Wax thickness
Conveyor speed
Production capacity
Source-listed construction and features
1. Designed for Duck & Goose Wax Processing
The equipment is specially developed for waterfowl processing lines.
Suitable for:
Duck
Goose
Other wax-treated poultry
2. Efficient Wax Solidification
The cooling system ensures:
Uniform wax hardening
Better wax peeling performance
Reduced feather residue
3. Stainless Steel Hygienic Structure
The tank is manufactured with food-grade stainless steel.
Applications and integration
The automatic duck wax cooling pool is mainly used in duck and goose slaughterhouses where wax dipping technology is applied.
During waterfowl processing, fine feathers around the skin are difficult to remove completely after scalding and mechanical plucking.
The waxing process covers remaining feathers with a wax layer. The cooling pool solidifies this wax coating, allowing the following dewaxing machine to remove wax and feathers together.
Typical applications include:
Duck meat processing plants
Goose slaughterhouses
Frozen duck export factories
Integrated waterfowl processing lines
The wax cooling stage directly affects the efficiency of the following dewaxing process and the appearance quality of finished products.
Selection conditions and project fit
Define product size, residence time, line speed, water quality, temperature, pressure, flow and drainage. Specify the hygiene process and acceptance method; a machine name does not establish a validated hygiene result.
Evidence, configuration and document status
The descriptions and tables below are source-listed reference information, not independently measured results. Confirm material grade, electrical supply, dimensions, duty, guards, controls and delivery scope in the approved quotation and drawing. No model-specific certificate or verified customer installation is established by this page. Request the document issuer, applicable model, scope and revision before relying on a compliance claim.
Source and version
Reference compilation R1, 2026-11-16. Supplied document: 2. 家禽屠宰设备 - 屠宰,烫 脱.doc; section 2.13. Configuration rows retain source units. Where the source lists alternatives or several models, each row must be checked as a separate configuration; a capacity or dimension must not be transferred between models.
Installation and process interfaces
State incoming product condition, process residence time, line speed, working height, water connections, drain location and access for cleaning or component removal. Check the full installation envelope, not only catalogue dimensions.
Utilities, control and feedback requirements
Use only the power, water, heating or cooling values given for the matching source configuration. Confirm operating pressure/flow or temperature, control method and line signals. A reference machine does not establish a validated hygiene or cooling result.
Maintenance and part identification
Request the configuration-specific manual and part references for nozzles, seals, pumps, sensors, conveying elements and any heating/cooling components fitted. Agree quantities and replenishment needs against actual duty and delivery experience. This page does not prescribe maintenance intervals, repairs or a guaranteed stock position.
Configuration-specific document checklist
Before purchase, identify the complete model and suffix, configuration table and drawing revision. Request the applicable layout/interface drawing, specification, manual, parts list and agreed inspection or test records. Performance curves or certificates should be linked only when an applicable original exists; a reference summary is not a substitute.
Source-unit confirmation required
The supplied reference does not explicitly state a unit for these fields: Cooling Temperature. The original entries are retained rather than assigning an assumed unit. Confirm the units, matching configuration and operating conditions before comparing these figures or approving a quotation.
Compare configurations for your project
For Duck Wax Cooling Pool for Poultry Processing Line, keep the complete identifier HT-WCP, HT-WCP1000, HT-WCP10000, HT-WCP3000, HT-WCP6000 attached to its own source configuration. Compare process duty, incoming animal or product range, target output, utilities, installation envelope and upstream/downstream interfaces under the same project conditions. A higher catalogue rate alone does not establish a better fit.
Start with this page's listed reference fields: Configuration basis: Multiple source variants; review the separate tables below. Confirm units, conditions and revision against the quoted configuration; do not transfer values to another model.
Compare alternative quotations only after each supplier identifies the complete model, configuration and matching documents. No universal suffix meaning or unsupported advantage over another model is asserted.
Purchasing review and enquiry preparation
Start with Duck Wax Cooling Pool for Poultry Processing Line and its specification/source notes. Download the linked reference summary, then request the original configuration-specific drawing and current technical documents. The summary is not an approved drawing, certificate or acceptance record.
Use the linked poultry processing application and purchasing guidance to review process interfaces, selection conditions and the proposed supply boundary. Verify which manufacturer, supplier and installation responsibilities are included; a reference photo does not establish factory ownership, certification or a completed HUATAO installation.
Before enquiry, prepare animal species or incoming product, size/weight range, target throughput, operating shifts, destination, available utilities and a layout or interface drawing. Quote HT-WCP, HT-WCP1000, HT-WCP10000, HT-WCP3000, HT-WCP6000 and identify the missing documents or conditions you need checked. Use the enquiry on this page so the product and original source page are retained.
| Parameter | Specification |
|---|---|
| Product Name | Automatic Duck Wax Cooling Pool |
| Brand | Huatao |
| Model Series | HT-WCP Series |
| Application | Duck / Goose Wax Cooling |
| Suitable Poultry | Duck, Goose, Waterfowl |
| Processing Section | Wax Cooling Section |
| Installation Position | After Wax Dipping Pool |
| Cooling Method | Chilled Water / Refrigeration System |
| Cooling Temperature | 4℃ - 8℃ Adjustable |
| Tank Material | SUS304 Stainless Steel |
| Plate Thickness | 2-3 mm |
| Conveyor Type | Overhead Shackle Conveyor |
| Operation Type | Continuous Cooling |
| Cooling Length | Customized |
| Production Capacity | 1000-10000 Birds/Hour |
| Water Circulation | Continuous Recycling System |
| Water Supply | Chilled Water System |
| Drainage System | Integrated Drain Outlet |
| Control System | Temperature Control Cabinet |
| Cleaning Method | Water Washing |
| Installation Type | Conveyor Integrated |
| Power Supply | 380V / 50Hz Customized |
| Model | Recommended Capacity |
|---|---|
| HT-WCP1000 | Up to 1000 BPH |
| HT-WCP3000 | Up to 3000 BPH |
| HT-WCP6000 | Up to 6000 BPH |
| HT-WCP10000 | Up to 10000 BPH |
| Item | Specification |
|---|---|
| Target Product | Wax-coated Duck / Goose |
| Cooling Medium | Cold Water |
| Cooling Temperature | 4-8℃ |
| Function | Wax Solidification |
| Process Result | Ready for Dewaxing |
Buyer FAQ
What is a duck wax cooling pool?
duck wax cooling pool is equipment used to cool and harden wax-coated duck or goose carcasses after waxing.
Why is cooling required after wax dipping?
Cooling solidifies the wax layer so that the following dewaxing machine can remove wax and fine feathers effectively.
Is this equipment suitable for chicken processing?
It is mainly designed for duck and goose processing because waterfowl require wax treatment for fine feather removal.
What cooling temperature is required?
Normally the cooling temperature is around 4-8℃, depending on wax type and production requirements.
What are the main wearing parts?
Main maintenance components include: Conveyor chains Water pumps Temperature sensors Drain filters
What information is needed to select this equipment?
Define product size, residence time, line speed, water quality, temperature, pressure, flow and drainage. Specify the hygiene process and acceptance method; a machine name does not establish a validated hygiene result.
Are these specifications an approved supply commitment?
No. These are source reference details. The quotation must identify the exact configuration, drawing revision, included documents and agreed acceptance criteria.
Related configurations and guidance
Reference specification and document status
This reference is not an approved manufacturing drawing, inspection report or certificate. Request the configuration-specific documents before purchase.